Hazardous Location Cranes
SafeLift Crane Aid supplies R&M Materials Handling Spacemaster® EX explosion-proof hoists and crane kits for Class I, Division 1 and Division 2 hazardous locations. We serve oil & gas, chemical, mining and potash operations across Saskatchewan and Northern Manitoba from our base near Saskatoon. Tell us your classification, capacity and span, and we'll help you configure the right hazardous location crane for your site.
Spacemaster® EX Class I, Division 1 Hoist
R&M Materials Handling
An explosion-proof wire rope hoist certified for Class I, Division 1 locations, where flammable gases or vapours may be present under normal operating conditions. Control commands and limit switches run on intrinsically safe circuits.
Hazardous location rating
• Class I, Division 1, Groups C & D, temperature class T4
• Additional marking: Class I, Zone 1, IIB, T4
• CSA C/US approved
What makes Div 1 different from Div 2
• Different hoisting and travelling motors
• Bigger hoist control panel
• Armoured cables instead of flexible conduit for the motors
• Intrinsically safe circuit for control commands and limit switches, with additional barrier relays
• Stainless steel hoist data and warning plates
Standard features
-
1–20 ton (1,000–20,000 kg) capacities
-
460 or 575 V / 3 ph / 60 Hz supply
-
Two-speed hoist, 6:1 ratio, contactor control
-
Two-speed trolley, 4:1 ratio, contactor control
-
Low headroom or normal headroom trolleys
-
Single or double reeved
-
Intrinsically safe-wired circuitry
-
Mainline contactor and control transformer
-
Pendant controller rated for hazardous locations

Spacemaster® EX Class I, Division 2 Hoist
R&M Materials Handling
The Spacemaster EX is the hazardous location version of R&M’s Spacemaster SX wire rope hoist. Its large-diameter drum gives low headroom, low wheel loads, near-true vertical lift with single reeving, and excellent hook approaches.
Hazardous location rating
• Class I, Division 2, Groups B, C & D, temperature class T3
• Additional marking: Class I, Zone 2, IIB+H2, T3
• CSA C/US approved
• ATEX 94/9/EC (manufacturers) and 1999/92/EC (users), as listed by R&M

Standard features
-
1–80 ton (1,000–80,000 kg) capacities
-
460 or 575 V / 3 ph / 60 Hz, or 380 V / 3 ph / 50 Hz supply
-
Two-speed hoist, 6:1 ratio, contactor control
-
Two-speed trolley, 4:1 ratio, contactor control
-
Low headroom, normal headroom and double girder trolleys
-
Single or double reeved
-
Spark-resistant wire rope as standard (EN 13463-5)
-
ASME H3 or H4 duty (FEM 1Am, 2m or 3m)
-
NEMA 4 and 7 control enclosure
-
Non-sparking options: bronze coated hooks, brass wheels, brass drop lugs on the trolley, stainless steel wire rope

Crane Kits
Explosion-Proof Crane Kits
Spacemaster EX modular crane packages are a one-stop solution for hazardous location cranes. They use pre-engineered R&M components, configured to your application, and are suitable for Class I, Division 2, Groups B, C & D, T3 locations. SafeLift Crane Aid can supply the complete kit for your crane builder or your own bridge build.
Standard crane features
• Top running or underrunning configuration
• 1.5–80 ton (1,600–80,000 kg) capacities
• Low headroom, normal headroom and double girder trolleys
• 460 or 575 V / 3 / 60 Hz, or 380 V / 3 / 50 Hz supply
• ASME H3 or H4 duty (FEM 1Am, 2m or 3m) hoist rating
• Two-speed hoist (6:1) and two-speed trolley (4:1), contactor control
• Low-maintenance sealed hoist brake
• NEMA 4 and 7 control enclosure
• Spark-resistant wire rope as standard (EN 13463-5)
• CSA C/US approved

Frequently Asked Questions About Explosion-Proof Hoists
What is the difference between a Class I, Division 1 and a Class I, Division 2 hoist?
Class I means flammable gases or vapours may be present. In Division 1 they may be present during normal operation, frequent maintenance or repair, or because of equipment failure. In Division 2 they are normally confined in closed containers, kept out by mechanical ventilation, or the area is next to a Division 1 location. The Spacemaster EX Div 1 hoist adds different motors, a larger control panel, armoured motor cables, intrinsically safe control and limit-switch circuits with barrier relays, and stainless steel data and warning plates.
Which groups and temperature classes do the Spacemaster EX hoists cover?
The Class I, Division 1 hoist is rated for Groups C & D, T4 (also marked Class I, Zone 1, IIB, T4). The Class I, Division 2 hoist is rated for Groups B, C & D, T3 (also marked Class I, Zone 2, IIB+H2, T3). Both carry the CSA C/US mark.
What capacities are available?
Division 1 hoists come in 1–20 tons (1,000–20,000 kg). Division 2 hoists come in 1–80 tons (1,000–80,000 kg). Division 2 crane packages come in 1.5–80 tons (1,600–80,000 kg).
What does "intrinsically safe-wired" mean?
Intrinsically safe circuits keep electrical and thermal energy below the level needed to ignite an explosive gas or dust atmosphere. On the Spacemaster EX Division 1 hoist, the control commands and limit switches use intrinsically safe circuits.
Are Spacemaster EX hoists CSA and ATEX approved?
Yes. Both models are CSA C/US approved. R&M also lists ATEX 94/9/EC (manufacturers) and 1999/92/EC (users) for the Spacemaster EX. Class and Division rated equipment can be used in the matching Zone-classified areas, as the NEC (505.9 and 505.20) and the Canadian Electrical Code (CEC C22.1) permit.
Can you supply a complete explosion-proof crane kit?
Yes. SafeLift Crane Aid supplies R&M Spacemaster EX modular crane packages for Class I, Division 2 locations, in top running or underrunning configurations from 1.5 to 80 tons. Options include non-sparking features such as bronze coated hooks, brass wheels and stainless steel wire rope.
Do you serve hazardous sites in Saskatchewan and Northern Manitoba?
Yes. SafeLift Crane Aid, a division of Venter Cranes in Langham near Saskatoon, supplies and supports R&M hazardous location hoists and cranes for oil & gas, chemical, mining and potash sites across Saskatchewan and Northern Manitoba, including inspections and maintenance.